Questions & Answers

My EVO ALL won't turn on when I go to program it. Are there any reoccuring problems with the D2D cables?

+1 vote
I just purchased the EVO ALL service #001A06307292. I installed it with a Crimestopper RS-7 G4 in my 2011 Honda Accord EXL V6. Everything is wired complete as per the wiring guide. The Crimestopper is all powered up, with trunk, parking lights, arm and disarm working fine.  Even the remote start will work if I leave a key in the ignithion. When I was ready to program the bypass, following the instructions, right at step one, the led lights never turned on. With my multi meter I checked for voltage on thje D2D cable. I only had 10.8 volts. My next step was to charge my battery. Now mind you, I have been an electrician for 28 years, and been installing  since the mid 80's.  I don't know what I could have overlooked, but right out of the box the unit is not powering up. Is there some sort of system reset that I can do, or is there something in the electronics which is restricting to electricity fllow and causing  voltage drop or lastly, is the bypass module just defective. I didn't want to void my warranty by opening up the unit but I rteally need to put my car back together. What should I do next?
asked Feb 15, 2014 in Jeep by Angelo Garcia (140 points)

1 Answer

0 votes

Hi Angelo,

 

Two easy tests

  1. Connect power and ground directly to the Red and Black wires of the datalink. Without any other connectors plugged in, insert the datalink without pressing on the programming button.
  2. Same thing as before as before but this time hold down the programming button.

Don't use the 12V and ground you used for the remote starter for those 2 tests, grab them elsewhere.


To reset the unit completely, the procedure is as follows: This will not work if you can't get the unit to power up though.

  1. Hold down programming button while plugging in datalink connector.
  2. Let go of button when LED is RED.
  3. Push and hold button again until all three LEDs start to alternate.
  4. Disconnect unit, she is now reset.

 

answered Feb 17, 2014 by Robert T (301,890 points)
...